Product Comparison

Features

Outdoor unit height is only 368mm, suitable for window A/C hoods

Easy to install without scaffolding (may be vary depending on different conditions)

Grade 1 Energy label

All DC Inverter cooling

Economy Mode

Powerful Mode

Quiet operation at a noise level as low as 21dB(A)

Outdoor Unit Low Noise

Moisture Removal

7 Steps Up/Down Directional Swing 

Automatic Flaps 

Auto Shut Flap

Automatic Air Flow Adjustment

Washable open panel, easily wash

On/Off Timer

Sleep Timer

Auto Restart

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 90 - 110 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 1 Energy Label

All DC nverter Cooling / Heating

R32 High Efficiency Refrigerant, reduces Global Warming Potential

Energy Saving operation by detecting movement of people 

Powerful Mode

Economy Mode

6 Steps Up/Down and 5 Steps Left/Right Directional Swing

Automatic Air Flow Adjustment

Auto Shut Flaps

Auto Restart

Moisture Removal

Sleep Timer

24hr Program Timer

Filter Sign

Washable Panel

Suggested area : 160 - 200 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)
Safety Tips for Air Conditioner

Outdoor unit height is only 408mm, suitable for window AC hoods

Easy to install without scaffolding work (may be vary depending on different conditions)

Grade 1 Energy label

All DC inverter cooling / heating

Economy Mode

Powerful Mode

Quiet Operation at a noise level as low as 29dB(A)

Outdoor Unit Low Noise

Moisture Removal

8 Steps Up/Down and 5 Steps Left/Right Directional Swing

Automatic Flaps

Auto Shut Flap

Automatic Air Flow Adjustment

Washable open panel, easily wash

On/Off Timer

Sleep Timer

Auto Restart

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 160 - 200 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

All DC Inverter cooling / heating

Economy Mode

Powerful Mode

Quiet Operation

Moisture Removal

6 Steps Up/Down and 5 Steps Left/Right Directional Swing

Automatic Flaps 

Auto Shut Flaps 

Automatic Air Flow Adjustment 

Auto Restart 

Sleep Timer 

Auto-Changeover 

Refrigerant R410A, Protect Earth Allopatric

Suggested area : 260 - 300 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 4 Energy Label

R32 High Efficiency Refrigerant, reduces Global Warming Potential

Quiet Operation

Moisture Removal

Wide Angle Airflow

Internal and external Blue condenser fins provide improved anti-rust performance

Instant Air Exchange 

Drain port is located at the bottom right rear of A/C unit

Suggested area : 210 - 250 sq.ft.

Safety Tips for Air Conditioner

Grade 1 Energy Label

All DC Inverter Cooling

R32 High Efficiency Refrigerant, reduces Global Warming Potential

Powerful Mode

Economy Mode

6 Steps Up/Down Directional Swing

Automatic Air Flow Adjustment

Auto Shut Flaps

Auto Restart

Moisture Removal

Sleep Timer

12hr Program Timer

Filter Sign

Washable Panel

PM2.5 Filter

Suggested area : 90 - 110 sq.ft.

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker. (Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

Safety Tips for Air Conditioner

Grade 1 Energy Label 
 
All DC Inverter Cooling / Heating
 
R32 High Efficiency Refrigerant, reduces Global Warming Potential
 
Powerful Mode
 
Economy Mode
 
6 Steps Up/Down Directional Swing
 
Automatic Air Flow Adjustment
 
Auto Shut Flaps
 
Auto Restart
 
Moisture Removal
 
Sleep Timer
 
12hr Program Timer
 
Filter Sign
 
Washable Panel
 
Suggested area : 90 - 110 sq.ft.  
 
Always use the remote controller to control the operation of the air-conditioner instead of the power breaker. (Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)

All DC Inverter Cooling / Heating

R32 High Efficiency Refrigerant, reduces Global Warming Potential

Energy Saving operation by detecting movement of people 

Powerful Mode

Economy Mode

6 Steps Up/Down and 5 Steps Left/Right Directional Swing

Automatic Air Flow Adjustment

Auto Shut Flaps

Auto Restart

Moisture Removal

Sleep Timer

24hr Program Timer

Filter Sign

Washable Panel

Suggested area : 210 - 250 sq.ft.  

Always use the remote controller to control the operation of the air-conditioner instead of the power breaker.(Turn off the power supply until the air-conditioner has been stopped for 2 to 3 min.)
Safety Tips for Air Conditioner

Cooling Capacity - Btu/h
22,314
Cooling Capacity - kW
6.54
EER Cooling - kW
3.00
Power Consumption - kW
2.180
Power Supply / Phase / Frequency - V / Ø / Hz
220 / 1 / 50
Dimensions (H x W x D) - mm
428 x 660 x 770
Net Weight - kg
61
Refrigerant
R32
Origin
China
Style
INVERTER WINDOW SPLIT TYPE
Inverter Wall Mounted Type
INVERTER WINDOW SPLIT TYPE
Inverter Wall Mounted Type
Inverter Wall Mounted Type
Inverter Wall Mounted Type
Inverter Wall Mounted Type
Cooling Capacity - Btu/h
9,000
18,000
18,100
27,300
9,200
8,500
28,000
Cooling Capacity - kW
2.65
5.28
5.30
8.00
2.70
2.50
8.21
Heating Capacity - Btu/h
18,000
18,100
30,000
10,900
30,000
Heating Capacity - kW
5.28
5.30
8.80
3.20
8.80
EER (Cooling) - kW
3.27
3.52
2.82
3.21
3.33
4.24
3.26
COP (Heating) - kW
4.13
4.05
3.61
4.16
3.79
Power Consumption (Cooling) - kW
0.81
1.50
1.88
2.49
0.81
0.59
2.52
Power Consumption (Heating) - kW
1.28
1.31
2.44
0.77
2.32
Voltage / Phase / Frequency - V / Ø / Hz
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
220/1/50
Dimension (I.U.) HxWxD - mm
268 x 840 x 203
280 x 980 x 240
295 x 940 x 270
320 x 998 x 238
270 x 784 x 224
270 x 784 x 224
340 x 1,150 x 280
Dimension (O.U.) HxWxD - mm
368 x 500 x 490
632 x 799 x 290
408 x 660 x 500
830 x 900 x 330
541 x 663 x 290
541 x 663 x 290
788 x 940 x 320
Net Weight (I.U. / O.U.) - kg
8.5 / 24
12.5/35
14 / 35
14/62
8.5/22
8.0/25
16/53
Remote Control
Wireless
Wireless
Wireless
Wireless
Wireless
Wireless
Wireless
Power Supply
Indoor
Outdoor
Indoor
Outdoor
Outdoor
Outdoor
Outdoor
Origin (Indoor)
China
Thailand
China
China
Thailand
China
Thailand
Origin (Outdoor)
Thailand
Thailand
Thailand
Thailand
Thailand
China
Thailand
Refrigerant
R410A
R32
R410A
R410A
R32
R32
R32